NEW QUESTION 19
A network architect is designing a new wired and wireless solution for for a company. The company has two buildings on a campus, which each building has three floors. The campus core will be placed in the basement of Building 1. Each wiring closet has eight strands of multi-mode OM3 grade fiber that connect to a wiring closet of the first floor of the building it is contained, referred to as a main distribution frame (MDF). The maximum distance between a floor's wiring closet and the MDF is 100 feet (30 meters). The maximum distance between the two MDFs and the campus core is no more than 150 feet (45 meters). There are eight strands of multi-mode OM3 grade fiber from these two MDF closets to the campus core.
Based on this information, which type of design should be used and what is the maximum speeds supported all uplinks for the existing the multi-mode fiber?
- A. two-tier and 10 Gbps
- B. three-tier and 10 Gbps
- C. three-tier and 40 Gbps
- D. two-tier and 40 Gbps
Answer: B
NEW QUESTION 20
A network architect has developed a design for a new Aruba Wi-Fi network that will include a hardware Mobility Master (MM) running the ArubaOS 8 4 operating system that will manage:
* Two clustered 7205 controllers with 300 campus APs
* Two clustered VMC-50 controllers with 75 remote APs
The architect plans on creating user roles, firewall policies, and wireless IPS policies on the controllers as well as implementing AirMatch. What would meet the license requirements for this scenario?
- A. LIC-MM-VA-500. LIC-MC-VA-50 (X2), LIC-AP <x375). PEF (x375). RFP (x375)
- B. LIC-MC-VA-50 (X2), LIC-AP (375), PEF (X375), RFP (X375)
- C. LIC-MC-VA-50 (x1), LIC-AP (300), PEF (X300). RFP (x300)
- D. LIC-MM-VA-50, LIC-MC-VA-50 (X1), LIC-AP (X300), PEF <x300). RFP (x300)
Answer: D
NEW QUESTION 21
A network architect is designing a new wireless solution for a company The company needs seamless roaming and client and AP active load balancing. The company also requires an Aruba Mobility Master (MM) to manage the wireless infrastructure. Which Aruba feature does the architect need to include in the design?
- A. Client Match
- B. IAP VC
- C. Clustering
- D. AirMatch
Answer: C
NEW QUESTION 22
A network architect needs to plan a new wireless network
- A. Airwave and Central only
- B. Central only
- C. Airwave, Central, Windows, Mac OSX, and Linux
- D. Airwave, Central, and Windows only
Answer: A
NEW QUESTION 23
A company is installing Internet of Things (loT) devices to support a smart and energy-efficient environment for a building, including loT devices for heating and air conditioning, lights, and window shades. loT devices of these types are typically classified as which category of devices?
- A. Nomadic devices
- B. Stationary devices
- C. Somewhat mobile devices (SMD)
- D. Highly mobile devices (HMD)
Answer: A
NEW QUESTION 24
A network architect plans to use two ArubaOS 5406 switches in a wiring closet configured in a VSF domain The VSF link requires a 40 GDps connection Which SFP+ transceiver solutions would meet this requirement?
- A. QSFP28
- B. SFP
- C. SmartRate
- D. QSFP+ LC
Answer: C
NEW QUESTION 25
Refer to the exhibit.
When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance?
- A. A + B
- B. A + C
- C. A + B + C
- D. A + B + C + D
Answer: D
NEW QUESTION 26
A network architect is designing a new Wi-Fi solution for a customer The customer currently occupies a one-story building on a small campus. In one part of the building there is an auditorium, where the ceiling height and attenuation is different from the rest of the building. What should the network architect create in VisualRF to identify this difference when planning :ne APs?
- A. Define the appropriate properties in the Building View
- B. Spit the Building View into two Floorplan Views
- C. Create a Region in the Floorplan View
- D. Define the appropriate properties in the Network View
Answer: A
NEW QUESTION 27
A network architect is creating a new wired design for a warehouse building. As a best practice, what length should the architect allow for the service loop in the wiring closets in this environment?
- A. 3-10 feet (1-3 m)
- B. 3 feet (1 m)
- C. 30-60 feet (10-20 m)
- D. 15-30 feet (5-10 m)
Answer: B
NEW QUESTION 28
A company needs an upgrade of its access layer switches. The solution requires that devices connected to the access layer by authenticated and their traffic processed by the firewall features of the Aruba Mobility Controllers. Which solution should the company implement?
- A. PAPI mobility
- B. GRE tunneling
- C. Dynamic segmentation
- D. iPsec tunneling
Answer: D
NEW QUESTION 29
A customer requires a campus core virtualization solution that supports a dual control and management planes, as well as active-active forwarding paths. Which solution would meet the customer's requirements?
- A. Mesh stacking
- B. VSX
- C. Backplane stacking
- D. VSF
Answer: C
NEW QUESTION 30
A customer has some employees that travel to various locations, where these employees will need Wi-Fi access at these locations. Because many of these locations do not have wireless support, the employees will need to carry an AP solution with them. Internet connectivity, if it doesn't exist at these locations, will be provided by a national phone company USB wireless card which will be connected to AP. The wireless solution needs minimal bandwidth, but needs to minimally support 802.1 lac wave 1 devices.
Which Aruba AP wireless solution would meet the needs of these employees most effectively and cost efficiently?
- A. 0
- B. 203R
- C. 1
- D. 303H
Answer: B
NEW QUESTION 31
A company has a warehouse that requires ruggedized APs to provide wireless access The APs need to support these characteristics:
* 2 or more spatial streams
* 802.11 ac and 802.11 n support
Cat 7 Ethernet cabling will be used to connect the APs to POE+ capable switches Link aggregation should be employed between the APs and the Ethernet switches. Which would be the most cost-effective solution that would meet the company's requirements?
- A. AP 365 with integrated omnidirectional antennas
- B. AP 375 with external omnidirectional antennas
- C. AP 510 with external omnidirectional antennas and plastic AP cover
- D. AP 318 with external omnidirectional antennas
Answer: D
NEW QUESTION 32
A company has two buildings on a campus, where each building has three floors, which two wiring closets per floor Assume that there will be 24 APs connected via POE+ to each wiring closet, along with 128 wired user connections. Which backplane stacking solution will provide the necessary Ethernet port capacity for all devices on Building 1 Floor 2 and is fully meshed?
- A. One 2930M 24-port POE+ switch and two 2930M 48-port switches per wiring closet
- B. One 381 OM 24-port POE+ switches and two 2930M 48-port switches per wiring closet
- C. Two 381 OM 24-port POE+ switches and three 381OM 48-port switches per wiring closet
- D. Two 2930F 24-port POE+ switches and three 2930F 48-port switches per wiring closet
Answer: A
NEW QUESTION 33
A network architect is designing a wireless solution for a company that is leasing one floor in a multi-floor building in a downtown area. The customer is concerned about ensuring complete Wi-Fi coverage and pin-pointing RF hazards. What type of survey should the network architect perform?
- A. Active
- B. Virtual
- C. Spectrum clearing
- D. Passive
Answer: A
NEW QUESTION 34
A university department has a program in video processing and editing. Students in the department use Wi-Fi to interact with the video servers. The editing and processing is done by the students accessing and using the video servers. However, the students must then stream their results, via Wi-Fi to their laptops to verify the results. A network architect has determined that no more than 20 APs will be needed for the Wi-Fi solution. Because of the large amount of bandwidth used during the streaming, the Aruba mobility controller solution will need to support 10 Gbps links.
Which solution would cost-effectively meet this customer's requirements?
- A. 0
- B. 1
- C. 7240XM
- D. 2
Answer: D
NEW QUESTION 35
A customer is designing a new wired network. The customer requires 50 Gbps uplinks, VSF logical switching, and smart rate port support Which of the following switches would meet these requirements?
- A. 5400R series
- B. 3810M series
- C. 8300 series
- D. 6300 series
Answer: B
NEW QUESTION 36
A network architect imports a floorplan defined in a PNG file format What is the function of the measurement tool in Aruba's VisualRF?
- A. Define the appropriate dimensions of each room in a Floorplan View
- B. Define the appropriate dimensions of a Floorplan and Building View
- C. Define the appropriate dimensions of a Floorplan View
- D. Define the appropriate dimensions of each object in a Floorplan View
Answer: D
NEW QUESTION 37
A network architect is doing a site survey for a new wireless design One concern the company has with the old wireless network is coverage. In some cases, APs would lose power and some employees in the network would lose wireless connectivity. The new design needs to prevent this issue from occurring. During the site survey, what are best practices to be followed in regards to the dBm signal level and the power of the AP to ensure adequate wireless coverage and minimal overlap of AP signals for the new design?
- A. AP power at 50% and a measurement of -65 dBM on the measuring device
- B. AP power at 75% and a measurement of -90 dBM on the measuring device
- C. AP power at 75% and a measurement of -80 dBM on the measuring device
- D. AP power at 100% and a measurement of -65 dBM on the measuring device
Answer: D
NEW QUESTION 38
A high-end theater venue will be implementing an Aruba wireless solution using ceiling- and wall-mounted APs. The venue wants to ensure the the APs blend into the ceiling and wall environments. What solution should the customer use to ensure that wireless coverage is not hampered?
- A. Paint the APs to match the ceilings or walls
- B. Place a strip of tape over the LEDs
- C. Order Aruba AP covers for the APs
- D. Place the APs above the ceiling and behind the walls
Answer: D
NEW QUESTION 39
A network architect is redesigning the access layer in a data center for a customer. The access layer requires fixed-port switches that support VSF and data center features like L2 VXLAN and REST-API Which switching solution should the network architect recommend?
- A. 3810M
- B. 0
- C. 2930F
- D. 1
Answer: C
NEW QUESTION 40
A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.
- A. A standalone 7008 controller per floor
- B. Two 7205 mobility controllers in a cluster
- C. Given this information, which Aruba solution would be the most cost-effective while still meeting the customer's requirements? O An IAP cluster per floor
- D. Two 7030 mobility controllers in a cluster
Answer: C
NEW QUESTION 41
A network architect plans to implement channel bonding in a new wireless design that involves dense deployment of APs. Which channel width would be optimal for this design?
- A. 40 MHZ
- B. 20 MHz
- C. 60 MHZ
- D. 10MHZ
Answer: C
NEW QUESTION 42
......